Full catalogue / Energy storage systems
LESSO · ARMENIA
Energy storage systems
Explore individual product photographs, size variants and technical data directly on this page.

Product video
Watch on YouTubeProducts and specifications
| Model / variant | Technical specification |
|---|---|
| Off-grid inverter with MPPT | LES-402A2AF-TFE · 4 kW · 24 V · 220/230/240 V AC |
| Off-grid inverter with MPPT | LES-622A4BF-TF · 6.2 kW · 48 V · 220/230/240 V AC |
| Hybrid inverter | LEC-622A4B2F-TF · 6.2 kW · 48 V · 220/230/240 V AC |
| Hybrid inverter | LEC-103A3B2F · 10 kW · 48 V · 230 V AC |
| Hybrid inverter | LEC-802A3BD-AT · 8 kW · 48 V · 230 V AC · IP66 |
| Hybrid inverter | LEC-123B3BD-AT · 12 kW · 48 V · 380/400 V AC · IP66 |
| Battery module | LSMO 25.6V120AH-ZY · 25.6 V · 120 Ah · 522 × 238 × 218 mm |
| Battery module | LYB-3K8BL7-TC · 3.84 kWh · 25.6 V · 150 Ah · IP65 |
| Floor-mounted home battery | LHD-51G230L-TC · 11.7 kWh · 51.2 V · 230 Ah · IP21 |
| Floor-mounted home battery | LHD-51F250L1A-BY · 12.8 kWh · 51.2 V · 250 Ah |
Detailed technical specifications
LES-402A2AF-TFE
| AC output voltage | 220 / 230 / 240 VAC ±5% |
|---|---|
| Output frequency | 50 / 60 Hz ±0.1% |
| Maximum PV input voltage | 500 VDC |
| MPPT voltage range | 60–500 VDC |
| MPPT trackers | 1 |
| Strings per MPPT | 1 |
| Maximum efficiency | 98% |
| No-load loss | ≤65 W |
| Relative humidity | 20–95% |
| Altitude | 1000 m; max 4000 m |
| Ingress protection | IP21 |
| Display | LCD |
| Communication interfaces | RS485 / RS232 / Wi-Fi |
| Transfer time | ≤20 ms |
| Rated output power | 4000 W |
| Peak output power | 8000 VA @100 ms |
| Rated output current | 17.4 A |
| Maximum PV input power | 5000 W |
| Maximum PV input current | 18 A |
| PV short-circuit current | 27 A |
| Battery voltage | 24 VDC |
| Battery voltage range | 21–30 VDC |
| Maximum charge current | 120 A |
| Maximum discharge current | 165 A |
| Operating temperature | −10…+40°C |
| Storage temperature | −15…+60°C |
| Package dimensions | 510 × 420 × 207 mm |
| Gross weight | 9.55 kg |
| Product dimensions | 436 × 330 × 138 mm |
| Net weight | 8.11 kg |
| Battery type | Lithium / lead-acid |
| Output waveform | Pure sine wave |
LES-622A4BF-TF
| AC output voltage | 220 / 230 / 240 VAC ±5% |
|---|---|
| Output frequency | 50 / 60 Hz ±0.1% |
| Maximum PV input voltage | 500 VDC |
| MPPT voltage range | 60–500 VDC |
| MPPT trackers | 1 |
| Strings per MPPT | 1 |
| Maximum efficiency | 98% |
| No-load loss | ≤65 W |
| Relative humidity | 20–95% |
| Altitude | 1000 m; max 4000 m |
| Ingress protection | IP21 |
| Display | LCD |
| Communication interfaces | RS485 / RS232 / Wi-Fi |
| Transfer time | ≤20 ms |
| Rated output power | 6200 W |
| Peak output power | 12400 VA @100 ms |
| Rated output current | 26.9 A |
| Maximum PV input power | 6200 W |
| Maximum PV input current | 27 A |
| PV short-circuit current | 36 A |
| Battery voltage | 48 VDC |
| Battery voltage range | 42–60 VDC |
| Maximum charge current | 120 A |
| Maximum discharge current | 143 A |
| Operating temperature | −10…+50°C |
| Storage temperature | −15…+60°C |
| Package dimensions | 565 × 397 × 200 mm |
| Gross weight | 11.57 kg |
| Product dimensions | 495 × 312 × 125 mm |
| Net weight | 10.33 kg |
| Parallel operation | 6 / max 9 |
| Standards / certificates | EN IEC60335-1 / EN IEC60335-2-29 / IEC62109-1 |
| Battery type | Lithium / lead-acid |
| Output waveform | Pure sine wave |
LEC-622A4B2F-TF
| Rated output power | 6200 W |
|---|---|
| Peak output power | 12400 W |
| Maximum PV input voltage | 500 VDC |
| PV short-circuit current | 36 A |
| Maximum PV input current | 27 A |
| MPPT trackers | 1 |
| MPPT voltage range | 60–500 VDC |
| PV voltage at full power | 360–430 VDC |
| Maximum PV input power | 8500 W |
| Battery voltage range | 42–60 VDC |
| Battery voltage | 48 V |
| Maximum charge current | 120 A |
| Maximum discharge current | 143 A |
| Maximum battery charge/discharge power | 5760 / 6900 W |
| AC output voltage | 220 / 230 / 240 VAC |
| AC input voltage range | 90–280 V ±3 V (APL); 170–280 V ±3 V (UPS) |
| Output frequency | 50 / 60 Hz |
| Bypass current | 26.9 A |
| Rated output current | 26.9 A |
| Motor load capacity | 2000 W |
| Power factor | 1.0 |
| Ingress protection | IP21 |
| Operating temperature | −10…+50°C |
| Package dimensions | 560 × 382 × 215 mm |
| Gross weight | 13.1 kg |
| Product dimensions | 465 × 313 × 135 mm |
| Net weight | 11.6 kg |
| Altitude | 1000 m; max 4000 m |
| Communication interfaces | RS485 / RS232 / Dry contact; Wi-Fi |
| Cooling method | Built-in fan |
| Battery type | Lithium / lead-acid |
| Overload capability | 11 s @105–150%; 2 s @150–200%; 400 ms @>200% |
LEC-103A3B2F
| Maximum PV input voltage | 500 V |
|---|---|
| PV short-circuit current | 28.75 / 28.75 A |
| Maximum PV input current | 23 / 23 A |
| MPPT trackers | 2 |
| MPPT voltage range | 125–435 VDC |
| PV voltage at full power | 240–425 VDC |
| Maximum PV input power | 16000 VA |
| Battery voltage | 48 V |
| Battery voltage range | 40–60 V |
| Maximum charge current | 200 A |
| Maximum discharge current | 200 A |
| Maximum battery charge/discharge power | 10000 W |
| AC output voltage | 230 VAC |
| AC input voltage range | 90–275 VAC |
| Output frequency | 50 / 60 Hz |
| Bypass current | 60 A |
| Rated output current | 45 A |
| Rated output power | 10000 W |
| Peak output power | 15000 W |
| Motor load capacity | 6 HP |
| Power factor | 0.8…0.8 |
| Ingress protection | IP20 |
| Operating temperature | −10…+55°C (>45°C derating) |
| Product dimensions | 620 × 445 × 130 mm |
| Net weight | 27 kg |
| Altitude | 2000 m |
| Cooling method | Built-in fan |
| Communication interfaces | RS485 / CAN / USB / Dry contact; Wi-Fi / GPRS |
| Battery type | Lithium / lead-acid |
| Electrical isolation | Non-isolated PV–AC; high-frequency isolation on battery side |
| Overload capability | 102–125%: 10 s; >125%: 5 s; 3 min; 5× |
LEC-802A3BD-AT
| MPPT trackers | 2 |
|---|---|
| Battery voltage | 48 V |
| Output frequency | 50 / 60 Hz |
| Power factor | 0.8…0.8 |
| Overload capability | >200% / 15 s |
| Output harmonic distortion | <3% / <1.5% |
| Ingress protection | IP66 |
| Operating temperature | −25…+60°C |
| Altitude | 2000 m |
| Maximum PV input voltage | 500 VDC |
| PV short-circuit current | 37.5 / 22.5 A |
| Maximum PV input current | 30 / 18 A |
| MPPT voltage range | 150–450 VDC |
| PV voltage at full power | 240–425 VDC |
| Maximum PV input power | 16000 W |
| Battery voltage range | 44–57 V |
| Maximum charge current | 190 A |
| Maximum discharge current | 190 A |
| Maximum battery charge/discharge power | 8000 W |
| AC output voltage | 220 / 230 VAC |
| Rated output current | 40 A |
| Rated output power | 8000 W |
| Maximum apparent power | 8800 VA |
| Overvoltage category | III (AC) / II (PV) |
| Package dimensions | 615 × 485 × 285 mm |
| Gross weight | 26 kg |
| Product dimensions | 554 × 427 × 198 mm |
| Net weight | 20 kg |
| Battery type | Lithium / lead-acid |
| Electrical isolation | Non-isolated PV–AC; high-frequency isolation on battery side |
LEC-123B3BD-AT
| MPPT trackers | 2 |
|---|---|
| Battery voltage | 48 V |
| Output frequency | 50 / 60 Hz |
| Power factor | 0.8…0.8 |
| Overload capability | >200% / 15 s |
| Output harmonic distortion | <3% / <1.5% |
| Ingress protection | IP66 |
| Operating temperature | −25…+60°C |
| Altitude | 2000 m |
| Maximum PV input voltage | 1000 VDC |
| PV short-circuit current | 45 / 22.5 A |
| Maximum PV input current | 36 / 18 A |
| MPPT voltage range | 200–800 VDC |
| PV voltage at full power | 350–800 VDC |
| Maximum PV input power | 24000 W |
| Battery voltage range | 40–60 V |
| Maximum charge current | 250 A |
| Maximum discharge current | 250 A |
| Maximum battery charge/discharge power | 12000 W |
| AC output voltage | 380 / 400 VAC (3W+N+PE) |
| Rated output current | 20 A |
| Rated output power | 12000 W |
| Maximum apparent power | 13200 VA |
| Overvoltage category | III (AC) / II (PV) |
| Package dimensions | 760 × 540 × 365 mm |
| Gross weight | 43.2 kg |
| Product dimensions | 683 × 475 × 256 mm |
| Net weight | 38 kg |
| Battery type | Lithium / lead-acid |
| Electrical isolation | Non-isolated PV–AC; high-frequency isolation on battery side |
LSMO 25.6V120AH-ZY
| Battery voltage | 25.6 V |
|---|---|
| Battery voltage range | 25.6–26.4 V |
| Nominal capacity | 120 Ah |
| Minimum capacity | 120 Ah |
| Initial impedance | ≤180 mΩ |
| Charge voltage | 28.8 V |
| End-of-discharge voltage | 18.4 V |
| Standard charge current | 50 A |
| Maximum charge current | 100 A |
| Standard discharge current | 50 A |
| Maximum discharge current | 100 A |
| Charging time | 2–3 h / 1–2 h |
| Cycle life | ≥4000 (80%; 0.2C / 0.5C) |
| Charging temperature | 0…55°C |
| Discharging temperature | −20…55°C |
| Storage temperature | 0…45°C (<1 month); 0…35°C (≤6 months) |
| Relative humidity | <75% RH |
| Product dimensions | 522 × 238 × 218 mm |
| Net weight | ≈25 kg |
| Standard test conditions | 25±2°C; ≤75% RH |
LYB-3K8BL7-TC
| Battery voltage | 25.6 V |
|---|---|
| Nominal capacity | 150 Ah |
| Nominal energy | 3.84 kWh |
| Usable energy | 3.84 kWh |
| Recommended charge current | 75 A |
| Maximum charge current | 150 A |
| Maximum discharge current | 150 A |
| Maximum discharge power | 3.8 kW |
| Charge voltage | 27.6 V |
| End-of-discharge voltage | 22.4 V |
| Cycle life | ≥3000 @100% DOD 1C; ≥5000 @80% DOD 1C |
| Depth of discharge | 100% |
| Discharging temperature | −20…60°C |
| Charging temperature | 0…45°C |
| Storage temperature | −5…35°C |
| Relative humidity | 60±25% RH |
| Altitude | ≤3000 m |
| Ingress protection | IP65 |
| Package dimensions | 283 × 575 × 290 mm |
| Gross weight | 31 kg |
| Product dimensions | 223 × 522 × 244 mm |
| Net weight | 29 kg |
| Cooling method | Natural cooling |
| Standards / certificates | UN38.3 / MSDS |
LHD-51G230L-TC
| Battery voltage | 51.2 V |
|---|---|
| Nominal capacity | 230 Ah |
| Nominal energy | 11.7 kWh |
| Usable energy | 11.7 kWh |
| Recommended charge current | 100 A |
| Maximum charge current | 200 A |
| Maximum discharge current | 200 A |
| Maximum discharge power | 10 kW |
| Charge voltage | 55.2 V |
| End-of-discharge voltage | 44.8 V |
| Cycle life | ≥4000 @100% DOD 1C; ≥6000 @80% DOD 1C |
| Depth of discharge | 100% |
| Discharging temperature | −20…60°C |
| Charging temperature | 0…45°C |
| Storage temperature | −5…35°C |
| Relative humidity | <95% |
| Altitude | ≤3000 m |
| Ingress protection | IP21 |
| Package dimensions | 1100 × 580 × 370 mm |
| Gross weight | 98 kg |
| Product dimensions | 750 × 442 × 230 mm |
| Net weight | 94 kg |
| Cooling method | Natural cooling |
| Standards / certificates | UN38.3 / MSDS |
| Display | LCD |
| Communication interfaces | RS485 / CAN |
LHD-51F250L1A-BY
| Battery voltage | 51.2 V |
|---|---|
| Nominal capacity | 250 Ah |
| Nominal energy | 12.8 kWh |
| Usable energy | 12.8 kWh |
| Recommended charge current | 100 A (max 150 A) |
| Maximum charge current | 100 A |
| Maximum discharge current | 150 A |
| Maximum discharge power | 8.5 kW |
| Charge voltage | 58.4 V |
| End-of-discharge voltage | 46 V |
| Depth of discharge | 90% |
| Discharging temperature | −20…55°C |
| Charging temperature | 0…50°C |
| Storage temperature | 10…35°C |
| Relative humidity | 65±20% RH |
| Altitude | ≤2000 m |
| Ingress protection | IP20 |
| Product dimensions | 472 × 360 × 831 mm |
| Net weight | 132.5 kg |
| Package dimensions | 925 × 575 × 555 mm |
| Gross weight | 152.5 kg |
| Display | LCD |
| Communication interfaces | RS485 / CAN |
| Cooling method | Natural cooling |
| Standards / certificates | UN38.3 / MSDS |
Let’s find the right solution
Contact LESSO Armenia for pricing, options, sizes and delivery.
Original catalogues · PDF
Download catalogues
Original PDF files
ARMENIA